The battery level indicators will illuminate as shown in Figure Table 5 shows the symbols and their meaning. Page Operation 3. Once the inverter LED has been illuminated, turn On the connected loads. Check the status indicators to determine whether the Liebert GXT3 is operating normally. Once the UPS has been shut down as detailed in 4.

Author:Shakam Fesida
Country:Argentina
Language:English (Spanish)
Genre:Sex
Published (Last):15 April 2013
Pages:398
PDF File Size:15.69 Mb
ePub File Size:16.32 Mb
ISBN:237-6-79750-815-4
Downloads:62831
Price:Free* [*Free Regsitration Required]
Uploader:Mazujinn



These features can minimize any surges or interference present in the mains power. In either operation mode, the UPS inverter is online, continuously generating clean, precise, regulated AC output power. AC input voltages may still Do not obstruct the air inlets on the front panel and rear panel of the UPS; blocking the air inlets reduces ventilation and heat dissipation, shortening the service life of the Liebert GXT3.

Page Tower Installation 2. If optional Liebert external battery cabinets will be connected to the Liebert GXT3, take out the spacers delivered with the battery cabinet. Connect the spacers and the support bases as shown in Figure 6. Each Liebert GXT3 needs two assembled support bases, one in the front and one in the rear.

The factory-supplied ears cannot support the weight of the UPS. Figure 15 Installing ears Each cabinet will increase the battery recharge time. Refer to 1. The battery cables are supplied with the battery cabinet.

Page Indicators The battery level indicator is composed of five sets of LED bars that illuminate and flash to indicate the battery capacity level. The battery level indicators will illuminate as shown in Figure Table 5 shows the symbols and their meanings. To ensure that the battery has adequate reserve power to protect the connected load, charge the battery for three hours before putting the UPS into service.

After the UPS has been shut down as detailed in 4. Wait 30 seconds and verify that all indicators have turned Off and the fan has stopped; this indicates that the power-off is complete. These instructions are available at: multilink. Page Usb Port Communication 5. For most users, the factory default settings will be adequate.

This section illustrates the features available for modifi- cation, as well as the factory default setting.