BRITONY COMBI SE PDF

Note a Chaffoteaux combination boiler can only supply heat to 1 source at any one time, either hot water or central heating but not both at the same time. The most common symtom of a faulty diverter valve is the lack of hot water at the hot tap. Other people realise that if they switch the central heating on they can get better hot water flow at the tap but again this only lasts for a short period of time. A good way of testing if this Chaffoteaux diverter valve is faulty is to turn the boiler off and let the central heating and boiler cool down, then turn the boiler back on but into hot water mode only. Run the hot tap and leave it running then go to the boiler, under the boiler there are 5 pipes 2 central heating pipes, 1 cold water feed pipe, 1 hot water pipe and a gas pipe touch the central heating pipes to see if 1 of them is getting hot, if one of them is then the diverter valve has failed because instead of diverting the heat generated by the boiler to to the hot tap its allowing the heat to go down the central heating.

Author:Nikor Kigami
Country:Kazakhstan
Language:English (Spanish)
Genre:Environment
Published (Last):4 February 2010
Pages:490
PDF File Size:16.95 Mb
ePub File Size:11.10 Mb
ISBN:142-5-44089-220-4
Downloads:23375
Price:Free* [*Free Regsitration Required]
Uploader:Vutilar



Note a Chaffoteaux combination boiler can only supply heat to 1 source at any one time, either hot water or central heating but not both at the same time. The most common symtom of a faulty diverter valve is the lack of hot water at the hot tap. Other people realise that if they switch the central heating on they can get better hot water flow at the tap but again this only lasts for a short period of time.

A good way of testing if this Chaffoteaux diverter valve is faulty is to turn the boiler off and let the central heating and boiler cool down, then turn the boiler back on but into hot water mode only.

Run the hot tap and leave it running then go to the boiler, under the boiler there are 5 pipes 2 central heating pipes, 1 cold water feed pipe, 1 hot water pipe and a gas pipe touch the central heating pipes to see if 1 of them is getting hot, if one of them is then the diverter valve has failed because instead of diverting the heat generated by the boiler to to the hot tap its allowing the heat to go down the central heating.

If you were to leave the hot tap running for a longer period of time the radiators would start to get hot. When fitting this diverter valve it is good practice to replace the fibre washers that connect the diverter valve to the pipe work.

Also some diverter valves are connected to the pipe work via O? To prevent the Chaffoteaux hydraulics parts from leaking once changed. We do supply a 5ml jar of silicone grease and we also supply a Diverter Valve generic washer kit please see the related products below. Note other customers have bought some or all of the products below when purchasing this product, please check to see if you require any of the products below.

Most genuine parts supplied by the manufacturer are packaged in original packaging authenticating their quality and origin. If other companies are selling this part at a substantially lower price than us there is a very good chance that their part is either compatible, re-conditioned, used or OEM.

Search By Part Number.

DIN EN 13306 PDF

Chaffoteaux Spares

The problems started 6 weeks ago, when the pressure gauge went all the way into the red when the central heating was on. After that happened, I was worried about using the central heating so I turned it off. The hot water still worked but it was not as hot as it used to be, and the system started to lose pressure whenever I used the hot water. There was also a leak coming from the bottom of the boiler. An engineer came out and said they would need to order some parts, and they mentioned something about the valve in the boiler. After they left, I had to top up the boiler several times a day, as whenever I used hot water the pressure would gradually drop and then the boiler would lock out.

COLOR CODED WITH TAJWEED RULES PDF

Second-hand Britony Combi Se for sale on UK's largest auction and classifieds sites

.

LES WENDAT PDF

Chaffoteaux Spares

.

JEAN CHATZKY DIFFERENCE PDF

Chaffoteaux & Maury Britony combi 80 Maintenance And Service Manual

.